COVERED ALUMINIUM CONDDUCTORS
Nominal cross sectional area of conductor (mm2) |
No.and nominal diameter of wires (mm) |
Nominal thickness of insulation (mm) |
Approx overall diameter (mm) |
Approx. Weight (kg/km) |
Current Rating | |
Bunched and enclosed in conduit two cables Single phase at 35¡æ (Amp) |
Clipped to a surface or on a cable tray bunched & unenclosed two cables single phase at 35¡æ (Amp) |
|||||
1.0re | 1/1.13 | 0.7 | 2.8 | 17 | 13 | 16 |
1.5re | 1/1.38 | 0.7 | 3.3 | 22 | 16 | 20 |
1.5rm | 7/0.50 | 0.7 | 3.5 | 23 | 16 | 20 |
2.5re | 1/1.78 | 0.8 | 3.9 | 35 | 22 | 28 |
2.5rm | 7/0.67 | 0.8 | 4.2 | 35 | 22 | 28 |
4.0rm | 7/0.85 | 0.8 | 4.8 | 55 | 30 | 37 |
6.0rm | 7/1.04 | 0.8 | 5.4 | 75 | 38 | 47 |
10rm | 7/1.35 | 1.0 | 6.8 | 115 | 52 | 63 |
16rm | 7/1.70 | 1.0 | 8.0 | 178 | 70 | 85 |
16rm | 19/1.04 | 1.0 | 8.1 | 180 | 70 | 85 |
25rm | 7/2.14 | 1.2 | 9.8 | 280 | 91 | 110 |
25rm | 19/1.30 | 1.2 | 9.9 | 280 | 91 | 110 |
35rm | 19/1.53 | 1.2 | 11.0 | 390 | 112 | 136 |
50rm | 19/1.78 | 1.4 | 13.0 | 525 | 136 | 164 |
70rm | 19/2.14 | 1.4 | 15.0 | 720 | 173 | 207 |
95rm | 19/2.52 | 1.6 | 17.0 | 1005 | 216 | 253 |
120rm | 37/2.03 | 1.6 | 19.0 | 1227 | 244 | 291 |
150rm | 37/2.25 | 1.8 | 21.0 | 1535 | - | 333 |
185rm | 37/2.55 | 2.0 | 23.5 | 1891 | - | 381 |
240rm | 61/2.52 | 2.2 | 26.5 | 2458 | - | 452 |
300rm | 61/2.52 | 2.4 | 29.5 | 3055 | - | 526 |
400rm | 61/2.85 | 2.6 | 33.5 | 4078 | - | 639 |
500rm | 61/3.20 | 2.8 | 37.0 | 5048 | - | 752 |
PVC-COVERED STRANDED ALL ALUMINIUM CONDUCTOR(AAC)
(Weather resistant Line Wire)
Nominal aluminium area mm2 | Wtranding and wire diameter mm | Approximate overall diameter of bare conductor mm | Calculated resistance per km at 20¡æ Ohm | Approximate breaking load KN | Approximate overall of covered conductor Type8 mm | Approximate mass per km of covered conductor Type8 kg |
22 | 7/2.6 | 6.18 | 1.227 | 3.99 | 8.2 | 100 |
50 | 7/3.10 | 9.30 | 0.5419 | 8.28 | 11.7 | 200 |
100 | 7/4.39 | 13.17 | 0.2702 | 16.00 | 16.0 | 360 |
200 | 19/3.78 | 18.90 | 0.1349 | 32.40 | 21.7 | 690 |
Nominal Aluminium area mm2 | Stranding and dinameter | Approximate overall diameter of bare conductor mm | Claculated resistance per km at 20¡æ Ohm | Approximate breaking load KN | Approximate overall diameter of covered conductor Type 16 mm | Approximate mass per km of covered conductor Type 16 kg | |
Aluminium mm | Steelmm | ||||||
25 | 6/2.36 | 1/2.36 | 7.08 | 1.093 | 0.61 | 10.7 | 190 |
50 | 6/3.35 | 1/3.35 | 10.05 | 0.5426 | 18.35 | 14.1 | 330 |
100 | 6/4.72 | 7/1.57 | 14.15 | 0.2733 | 32.70 | 18.2 | 550 |
150 | 30/2.59 | 7/2.59 | 18.13 | 0.1828 | 69.20 | 22.2 | 920 |
150 | 18/3.25 | 1/3.35 | 16.75 | 0.1815 | 35.70 | 20.8 | 680 |
175 | 18/2.79 | 7/2.79 | 19.53 | 0.1576 | 79.80 | 23.6 | 1050 |
175 | 18/3.61 | 1/3.61 | 18.05 | 0.1563 | 41.10 | 22.1 | 780 |
200 | 30/3.00 | 7/3.00 | 21.00 | 0.1363 | 92.25 | 25.0 | 1190 |
200 | 18/3.86 | 1/3.86 | 19.30 | 0.1367 | 46.55 | 23.3 | 870 |
Nominal aluminium area mm2 | Stranding and wire dinameter mm | Approximate overall diameter of bare conductor mm | Calculated resistance per km at 20¡æ Ohm | Approximate breaking load KN | Approximate overall of covered conductor Type16mm | Approximate mass per km of covered conductor Type16kg |
25 | 7/2.34 | 7.02 | 1.094 | 8.44 | 10.6 | 170 |
50 | 7/3.30 | 9.90 | 0.5498 | 16.80 | 13.9 | 280 |
100 | 7/4.65 | 13.95 | 0.2769 | 33.30 | 18.0 | 470 |
150 | 19/3.48 | 17.40 | 0.1830 | 50.65 | 21.4 | 680 |
175 | 19/3.76 | 18.80 | 0.1568 | 59.10 | 22.8 | 780 |